ELISA Tissue Homogenizer Low Temperature
20% OFF list price as part of our FALL Sale! On now until October 18th, 2024!
Product Introduction
SWE-FP is a newly upgraded low-temperature homogenizer, which can reach a temperature as low as -50℃ in the chamber and also equipped with a freezing table. Adopt high-speed reciprocating motion of the vertical shaking system, the frozen sample in the grinding tube collides with the grinding bead, and the resµLting grinding shear force and impact force completely break down the tissue. Up to 192 samples can be processed simµLtaneously in one minute, making it a dedicated device that meets the requirements of rapid processing of mµLti-sample.
Product Features
1. Slider drive, no wear shaft, noise stability and durability;
2. Equipped with low temperature freezing table. It can meet the needs of sample storage, electrophoresis, membrane transfer and other low-temperature experiments
3. Imported compressor, lowest cooling temperature of -50℃,low temperature grinding throµghout the process, reducing degradation of proteins and RNA.
4. Up to 192 samples can be processed simµLtaneously in 1 minute (24 samples can be processed with standard),efficiently and effectively completing sample grinding with high throµghput.
5. MµLtiple adapters to choose.
Technical Parameters
1. Dimensions: Length 650mm,Width 420mm,Height 430mm
2. Weight:54 kg
3. Screen Quantity:5 inches
4. Temperature:-50℃
5. Temperature control precision:±1℃
6. Working time:Runtime0-9999s,pausetime0-999s,andruntimes1-99times
Parameters Comparison
Cat. No.
KZ-III
KZ-III-F/FP
KZ-5F-3D
SWE-FP
Operating mode
The vertical shaking system moves back and forth at high speed.
the vertical shaking system moves back and forth at high speed
Move in a "∞" shaped three-dimensional motion in space.
The vertical shaking system moves back and forth at high speed.
Temperature
Room temperature
-10℃/-40℃
-40℃
-50℃
Temperature control precision
N/A
±1℃
±1℃
±1℃
Standard spec.
24*2 mL
24*2 mL
24*2 mL
24*2 mL
Maximum sample volume
60 pcs
60 pcs
24 pcs
192 pcs
Adapter specification
24x0.5mL. 24x2mL. 32x2mL. 48x2mL. 60x2mL. 12x5mL. 10x10mL. 6x5mL (steel can). 4x30mL (steel can). 2x50mL (steel can) and 8*15mL (steel can)
24*2mL.
12*5mL(Optional )
24x0.5mL.24x2mL.48x2mL.
32x2mL.60x2mL.96x2mL.
12x5mL.10x10mL.4x30mL(steel can).
6x5mL(steel can).8x15mL(steel can)
2x50mL(steel can).96x2mL(2pcs 96-deep well plate)
Freezing table
N/A
N/A
N/A
YES
Adapter fixing method
Nut
Nut
Knob cover with safety locking device
Nut
Working time
0-99min99s
0-99min99s
0-99min99s
0-99min99s
Dimensions
365*265*396mm
370*365*500mm
650*420*430mm
Screen Quantity
5 inches
5 inches
5 inches
5 inches
Emergency stop button
YES
YES
YES
YES
Electromagnetic safety lock
Screen click control with automatic power-off unlocking. the cover cannot be opened during operation until the grinding program ends, fµLly protected.
Maximum feeding Quantity
No requirements, adjustable according to the adapter.
Weight
30.7kg
45kg
52kg
54kg
Power parameters
200-240VAC,50-60 Hz,
200 W
200-240VAC,50-60 Hz,
400 W
200-240V AC,50-60 Hz,
400 W
200-240VAC,50-60 Hz,500 W
Cooling method
Low temperature pre-cooling: adapter can reach -80℃ or liquid nitrogen pre-cooling
Compressor cooling
Compressor cooling
Compressor cooling
Transport screws
Yes (2 at the bottom)
Yes (2 at the bottom)
N/A
Yes (2 at the bottom)
Advantages
Small Quantity, cost-effective
Compatible with various adapter specifications.
Freezing function, lowest temperature can reach -40℃.
Higher grinding efficiency, reducing tissue degradation. Freezing function, lowest temperature can reach -40℃.
Lower cooling temperature can reach -50℃. low temperature freezing table,
Protects samples and meets low-temperature needs for Western Blot experiments, electrophoresis, and transfer membranes.
Unboxing and Installation
Remove the high-speed low-temperature tissue grinder from the packaging box and place it in a suitable location. Confirm that all components are complete.
Use the wrench provided in the accessories to remove the two fastening screws at the bottom of the instrument. (Before the first grinding operation, make sure to remove the fastening screws.)
Place the machine on a level and flat laboratory bench to prevent vibrations during operation.
Let it stand for 10 hours to ensure the coolant is in place. Connect the power supply (200-240V) and turn on the power switch at the back of the grinder.
Turn on the compressor cooling switch and wait for 10-15 minutes. Observe if the temperature in the grinding chamber reaches the set temperature.
6.If the temperature reaches the set temperature, install the adapter and nut correctly, then cover the top and start the machine.
Sample Preparation
The adapter can be used to grind 96 samples simµLtaneously in a 96-well plate. The adapter includes a base that can hold a 96-well plate, a top cover, and a locking nut.
Take the samples to be ground and place them in the grinding tubes. It is recommended to use no more than 100mg of sample. Add the corresponding extraction solution, ensuring that the total volume of the sample and extraction solution is within half of the overall volume. Add a few appropriately Quantityd grinding beads. To ensure grinding efficiency and quality, for larger volume samples, it is recommended to cut them into smaller pieces using scissors.
Unscrew the locking nut and remove the top cover. Place the grinding tubes into the adapter, then attach the top cover and tighten the locking nut in a clockwise direction. (The placement of the tubes shoµLd follow the principles of symmetry and balance.)
Operation Steps
Plµg the power cord of the grinder into a grounded 220V power outlet, and turn on the power switch at the back of the grinder.
After the startup interface is displayed, wait for about 5 seconds to enter the main operating interface.
Once the grinder is turned on, the cooling system starts running. Place the grinding tubes containing the samples, tighten the adapter, and cover the top of the grinder.
Set the operating frequency, time, and number of cycles. Click the "Temperature Selection" button to choose the temperature mode and set the desired temperature for the grinding chamber or the cooling platform.
Click the start button to begin the grinding process. The instrument will automatically stop once the timer reaches zero.
Equipment Maintenance
Perform the following routine maintenance after each use to ensure the reliable operation of the grinder.
Make sure to turn off the power and unplµg the power cord before cleaning.
If solvents, salt water, acidic or alkaline solutions are spilled on the grinder, immediately wipe them clean with a damp cloth to avoid damaging the instrument.
Do not use high-pressure sterilization on any part of the grinder, including the adapter.
The components of the adapter shoµLd be cleaned after use. Use an appropriate cleaning agent, rinse with distilled water, and then wipe dry with a paper towel.
After using an appropriate cleaning agent, wipe the grinder clean with a soft cloth.
The following disinfectants and cleaning agents are recommended for cleaning the grinder and adapter:
a) Ordinary cleaning agent
b) Neutral detergent
c) 70% alcohol content
Equipment List
No.
Product Name
Model/Specification
Quantity
Remarks
1
Tissue Homogenizer
SWE-FP
1
2
Standard Hollow Adapter
2mL*24
1
Can process 24 samples at once
3
Beads Pen
SYM-04Z
1
Suitable for 2mL grinding tubes, zirconia beads 4mm
4
Beads Pen
SYM-04B
1
Suitable for 2mL grinding tubes, steel beads 4mm
5
Beads Pen
SYM-03B
1
Suitable for 2mL grinding tubes, steel beads 3mm
6
2mL Centrifµge Tube
1
Tube wall is thickened, material strength is higher, and there is no RNA enzyme.
Protein Extraction
Product Name
Grinding Beads
Frequency
Grinding Time
Pause Time
Cycle times
Recommended Extraction Solution
Plant Stems, Leaves
Stainless Steel Beads 3mm*3, 4mm*1
60Hz
60s
15s
3
Protein Extraction Solution
Heart, Liver, Spleen, Lungs, Kidneys, Brain of Mice and Rats
Stainless Steel Beads 3mm*2, 4mm*1
60Hz
30s
15s
2
Protein Extraction Solution
Stomach, Intestines, Muscles, Fat, Pancreas of Mice and Rats
Stainless Steel Beads 3mm*2, 4mm*1
60Hz
45s
15s
2
Protein Extraction Solution
Skin, Ears, Tail, Blood Vessels of Mice and Rats
Stainless Steel Beads 3mm*3, 4mm*2
70Hz
60s
20s
3
Protein Extraction Solution
Cartilage, Hair, Hard Bones of Mice and Rats
Stainless Steel Beads 3mm*4, 4mm*2
70Hz
90s
20s
3
Protein Extraction Solution
(This condition is for reference only, and can be adjusted at any time during the experiment according to the grinding effect.)
RNA Extraction
Product Name
Grinding Beads
Frequency
Grinding Time
Pause Time
Cycle times
Recommended Extraction Solution
Plant Stems, Leaves
Zirconia Beads 3mm*3, 4mm*1
60Hz
60s
15s
3
RNA Extraction Solution
Heart, Liver, Spleen, Lungs, Kidneys, Brain of Mice and Rats
Zirconia Beads Beads 3mm*2, 4mm*1
60Hz
30s
15s
2
RNA Extraction Solution
Stomach, Intestines, Muscles, Fat, Pancreas of Mice and Rats
Zirconia Beads Beads 3mm*3, 4mm*2
60Hz
45s
15s
2
RNA Extraction Solution
Skin, Ears, Tail, Blood Vessels of Mice and Rats
Zirconia Beads Beads 3mm*4, 4mm*2
70Hz
60s
20s
3
RNA Extraction Solution
Cartilage, Hair, Hard Bones of Mice and Rats
Zirconia Beads Beads 3mm*3, 4mm*4
70Hz
90s
20s
3
RNA Extraction Solution
(This condition is for reference only, and can be adjusted at any time during the experiment according to the grinding effect.)
For RNA extraction, the grinding time is extended compared with that of protein extraction, and RNA extraction solution is added to the grinding, the specific grinding time depends on the amount and type of tissue to be ground. Samples difficµLt to break can be repeated grinding 2-3 times, the specific situation can be adjusted appropriately according to the experiment.
Strong and Toµgh Tissue Grinding
For samples that are difficµLt to grind (e.g. cartilage, hair, etc.), we recommend using a 2mL grinding tube. Cut the sample into 1-2mm pieces, add the appropriate number of grinding beads, cover the tube tightly and freeze in liquid nitrogen for 2-3min without extracting solution, dry grind for 60 seconds at 70Hz, then add extracting solution to the tube and repeat the grinding once. If the grinding resµLt is not satisfactory, the tube can be frozen again and the above experimental steps can be repeated.
Bone Tissue Grinding
For bone tissue, use the special steel grinding jar and adapter. The bone tissue is first frozen in liquid nitrogen for 5-10min, then put into the grinding jar, add the steel beads, and grind for 180 seconds at 70Hz (set cycle grinding). After grinding, take out the finished tissue, put it into a 2mL grinding tube, add the extraction solution, two 3mm grinding beads and homogenize for 60 seconds.
Cat. No.
Product Name
Spec.
KZ-5F-3D
3D Tissue Homogenizer (-40℃)
(-40℃)
KZ-III
Tissue Homogenizer (Room Temperature)
Room Temperature
KZ-III-96
Tissue Homogenizer Room Temperature (96-well Plate)
Tissue Homogenizer Room Temperature (96-well Plate)
KZ-III-F
Tissue Homogenizer Low-temperature (-10℃)
(-10℃)
KZ-III-FP
Tissue Homogenizer Low-temperature (-40℃)
(-40℃)
KZ-III-YLS
Water-quality Chlorophyll Homogenizer
Room Temperature
SWE-FP
Tissue Homogenizer Low Temperature (-50℃, Freezing Table)
(-50℃, Freezing Table)
Référence interne:
SWE-FP
URL de site web:
/shop/swe-fp-elisa-tissue-homogenizer-low-temperature-176136
Your Dynamic Snippet will be displayed here...
This message is displayed because youy did not provide both a filter and a template to use.
Our latest content
Check out what's new in our company !
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.