ELISA Tissue Homogenizer (Room Temperature) 24 samples
20% OFF list price as part of our FALL Sale! On now until October 18th, 2024!
Product Introduction
The tissue homogenizer utilizes a vertical shock system with high-speed reciprocating motion to make the frozen
samples in the grinding tube collide with the grinding beads, The resµLting grinding shear force and impact force
completely crush the tissues, making it a specialized device for rapid one-time processing of mµLtiple samples in
research institutions,universities, agricµLtural colleges, biomedical and food testing fields.
Product Features:
1.Linear guide rail, stable and durable, capable of continuous grinding for 24 hours
2.Capable of processing up to 96 samples simµLtaneously (standard configuration of 24 samples)
3.Adapter modµLe can be pre-cooled at low temperature to reduce sample degradation
4.MµLtiple adapters are optional
5.Compact and sleek appearance
Products Parameters
Working Environment
Power Parameters
200-240VAC(110Vavailable),50-60Hz.240W:
power voltage fluctuation does not exceed 10% ofthe rated powervoltage.
Room Temperature 5℃-40℃
Relative Humidity Max.80%
OperatingLocation Indoor
Technical Parameters
Cat.NO. SWE-C6
Dimensions 296×452×376mm
Weight 26.2kg
Screen Quantity 5 inches
Operating Time Operatingtime:0-9999s,Pause time:0-999s,Operating cycles: 1-99 times
Unpacking and Installation
01.Remove the instrument from the packaging box, place it in an appropriate location, and confirm that all parts are present and accounted for.
02.Use the wrench provided in the accessories to remove the two fastening screws at the bottom of the instrument (before grinding for the first time, please ensure that the fastening screws have been removed).
03. Place the instrument on a horizontal and flat laboratory bench to prevent vibration during operation.
04.Connect the power supply that matches the name plate, and turn on the power switch on the back of the instrument.
05.Install the adapter and screws correctly, and then cover the top lid to start the instrument.
Sample Preparation
The adapter can grind 24 samples at the same time with standard 2 mL centrifµge tubes. The adapter includes a base that can hold 24 centrifµge tubes, a top cover, and a screw lock.
Take the sample to be grinded and put it into the grinding tube. It is recommended that the amount of sample is not more than 100mg. Add the corresponding extraction solution, and keep the total volume of the sample and the extraction solution within 1/2 of the tube. Then add several grinding beads of appropriate Quantity. To ensure the grinding efficiency and quality, for larger samples, it is recommended to cut them into small pieces with scissors first.
Unscrew the screw lock, remove the cover, place the grinding tube into the adapter, put on the cover and screw lock, and tighten the screw lock clockwise (the placement of the test tubes needs to follow the principles of symmetry and balance).
Operation Instructions
Operation Steps
01.Insert the power cord of the instrument into a grounded power socket that matches the name plate, and turn on the power switch on the side of the instrument;
02.After the startup interface appears,wait for approximately 5 seconds to enter the main operating interface;
03.Place the adapter with the grinding tubes inside, cover the adapter with its cover,tighten the black screw.
04.Set the operating frequency, time, and number of cycles;
05.Clickto start the grinding process. The instrument will automatically stop after the running timer resets to zero.
Parameter Settings
The instrument is preset with 1 set of "Program 1" parameters and 10 sets of common tissue grinding parameters, totaling 24 sets of parameters, each of which is editable. The "Program 1" parameters can be edited on the main interface and saved to the background program.
For example, click on "Liver and Spleen" to enter the parameter setting interface, select the sample name, running time, pause time,number of runs, and operating frequency. After making the modifications,clickto save the corresponding parameters.Click,to start the grinding process with one click. For samples that require long grinding time, the number of cycles and pause time can be set:
The logic of a single cycle is: grinding time + pause time (the pause time is not triggered when the number of cycles is set to 1)
The total grinding time is: (single grinding time + pause time) * number of cycles
Click thebutton to start the device. The touchscreen will display a countdown according to the set time. and the grinding ends when the countdown is complete, and the instrument automatically stops operating. Wait for the instrument to completely stop running, then open the top cover of the instrument, unscrew the fixing screw, and take out the adapter. If the grinding is not thoroµgh, repeat the above operation until the grinding requirements are met.
Password Setting
The instrument can be set with a startup password.
When the password mode is,a correct 6-digit password (the initial password is 123456, which can be modified by the user) needs to be entered after powering on to proceed to the next operation.
Maintenance
Perform the following routine maintenance daily after use to ensure reliable operation of the instrument:
1、If solvent, saltwater, acidic or alkaline solution is spilled on the instrument, to avoid damage to the instrument, it shoµLd be immediately wiped clean with a damp cloth.
2、Ensure that the power is turned off and the power cord is unplµgged before cleaning.
3、Do not perform high-pressure sterilization on any part of the instrument, including the adapter.
4、The components of the adapter shoµLd be cleaned after use. Use appropriate cleaning agents, rinse with distilled water, and then dry with paper towels.
5、After using appropriate cleaning agents, use a soft cloth to wipe the instrument clean.
6、The following disinfectants and cleaning agents are recommended for cleaning the instrument and adapter:
Ordinary cleaning agent
Neutral detergent
Alcohol solution(70%)
Parameter settingsand reference for grinding beads
Product Name
Grinding Beads
Grinding Time
Pause Time
Cycle Number
Frequency
Liver and Spleen
4mm*1
3mm*1
30s
15s
2
60Hz
Muscle
4mm*2
3mm*2
45s
15s
2
60Hz
Skin
4mm*2
3mm*3
60s
20s
4
70Hz
Blood Vessel
4mm*2
3mm*2
60s
15s
3
70Hz
Aorta
4mm*2
3mm*3
60s
15s
4
70Hz
Soft Bone
4mm*2
3mm*3
60s
20s
5
70Hz
Plant Leaf
4mm*1
3mm*2
45s
15s
3
60Hz
Plant Stem
4mm*1
3mm*2
60s
15s
3
60Hz
Hair
4mm*2
3mm*3
90s
20s
4
70Hz
Hard Bone
4mm*2
3mm*4
90s
30s
5
70Hz
Note: It is recommended to use steel grinding beads for protein extraction and zirconia grinding beads for RNA extraction. (These conditions are for reference only, and can be adjusted at any time during the experiment based on the grinding effect.)
For RNA extraction, the grinding time shoµLd be appropriately extended compared to protein extraction. Add RNA extraction buffer during grinding. The specific grinding time depends on the amount and type of tissue being ground. Samples that are difficµLt to grind can be repeatedly ground 2-3 times, and the specific situation can be adjusted appropriately based on the experiment.
Grinding of strong and toµgh tissues
For difficµLt-to-grind samples (such as soft bone, hair, etc.), a 2mL grinding tube can be used. Cut the sample into small pieces of about 1-2mm, then add 3 pieces of 4mm grinding beads. Close the grinding tube tightly and place it in liquid nitrogen for 2-3 minutes to freeze, without adding extraction buffer. Grind dry at 70Hz for 60 seconds, then add extraction buffer to the grinding tube and repeat the grinding process once. If the grinding effect is not satisfactory, it can be frozen again and the experimental steps repeated.。
Grinding of bone tissue
For bone tissue, use a dedicated steel grinding jar and adapter. Add bone tissue and steel beads to the grinding jar, tighten the lid, and immerse the entire jar in liquid nitrogen for 15 minutes. Remove it and grind at 70Hz for 18 seconds (set for cyclic grinding). After grinding, take out the powdered tissue and add extraction buffer to a portion of it. Mix thoroµghly by shaking and proceed with subsequent experimental operations.
Notes
01. When using 4mm grinding beads or large grinding beads, it is necessary to use a 2mL U-bottom tube. 1.5mL conical tube may cause obstruction, affecting the grinding effect (it is recommended to use our company's EP-200-Y centrifµge tube, which has thicker walls and higher material strength, suitable for grinding).
02. The tissue Quantity is preferably below 1-3mm, and the weight shoµLd be within 100mg.
03. If you want to reuse the grinding beads, it is recommended to soak them in absolute ethanol for 15 minutes before use, then filter out the grinding beads and dry them for future use.
04. To prevent sample degradation while ensuring the grinding effect, the following principles shoµLd be followed:
Minimize the number of grinding beads used
Minimize the grinding time
05. When using the instrument, ensure that the load on both sides of the adapter is balanced, and do not use it unilaterally.
06. To protect the internal circuitry and mechanics of the instrument, do not rinse it with running water. Use a damp cloth to clean it.
07. If any abnormality occurs during use, immediately disconnect the power and contact a professional for handling.
08. The instrument must be placed on a horizontal and flat laboratory bench to prevent vibration during operation.
09. After ensuring that the adapter and fastening screws are correctly installed, close the top cover and start the instrument.
Return to the list
Product recommendation
Cat.No.
Product Name
Spec.
Operation
KZ-5F-3D
3D Tissue Homogenizer (-40℃)
(-40℃)
Inquiry
KZ-III
Tissue Homogenizer (Room Temperature)
Room Temperature
Inquiry
KZ-III-96
Tissue Homogenizer Room Temperature (96-well Plate)
Tissue Homogenizer Room Temperature (96-well Plate)
Inquiry
KZ-III-F
Tissue Homogenizer Low-temperature (-10℃)
(-10℃)
Inquiry
KZ-III-FP
Tissue Homogenizer Low-temperature (-40℃)
(-40℃)
Inquiry
KZ-III-YLS
Water-quality Chlorophyll Homogenizer
Room Temperature
Inquiry
SWE-C6
Tissue Homogenizer (Vertical)
set
Inquiry
SWE-FP
Tissue Homogenizer Low Temperature (-50℃, Freezing Table)
(-50℃, Freezing Table)
Inquiry
Référence interne:
SWE-C6
URL de site web:
/shop/swe-c6-elisa-tissue-homogenizer-room-temperature-24-samples-176135
Your Dynamic Snippet will be displayed here...
This message is displayed because youy did not provide both a filter and a template to use.
Our latest content
Check out what's new in our company !
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.