Se rendre au contenu

ELISA ECLiPico™ ECL Chemiluminescence

https://assay.labm.com/web/image/product.template/29425/image_1920?unique=388ec86
(0 avis)
30% OFF list price as part of our FALL Sale! On now until October 18th, 2024! Description ECLiPico™ ECL Chemiluminescence Kit is a highly sensitive chemiluminescence kit based on luminol ECL chemiluminescence. This product can react with horseradish peroxidase (HRP) conjµgated on secondary antibody to produce fluorescence. Samples are examined by X-ray lithography or other appropriate fluorescence imaging equipment (CCD camera, etc.). It is used for developing Western blots with high sensitivity and more stable color development, which was suitable for the detection of mid to relatively low abundance target protein. This product is indicated for the detection of target proteins is less than or equal to picogram range. Storage and Handling Conditions Transport with wet ice; Store at 4℃ away from light, valid for 12 months. If not used for a long time, it can be stored at -20℃. Component Kit Quantity ECL02 ECL A solution ECL02 ECL B solution 100mL 50 mL 50 mL 200mL 100 mL 100 mL 800mL 400 mL 400 mL Assay Protocol Preparation of hypersensitive ECL working solution: Mix the ECL A solution and ECL B solution in equal volumes, and store at 4℃away from light. This mixture shoµLd be prepared before use.. In Western experiment, PVDF membrane was incubated with secondary antibody, washed several times, and excess liquid was absorbed by filter paper. Stick two layers of PE gloves or other transparent films on the exposure box, place the protein side of the PVDF film between the two layers of the exposure box, add the mixed ECL working solution to cover the film and place it on the film for 1-2 min. Remove the ECL working liquid with filter paper or absorbent paper, cover the upper film and start pressing the film. The pressed film shoµLd be developed and fixed with developing and fixing reagents. Adjust exposure conditions according to luminous intensity. Note: High sensitive ECL A liquid and high sensitive ECL B liquid in the pipetting process, the pipette tip must be replaced. The reciprocal contamination of liquid A and liquid B will lead to the gradual failure of liquid A or liquid B. In addition, the contamination of metal ions will reduce the sensitivity of this reagent, please pay attention to the use of clean pipette tip. Store sealed after use. If the background is very deep after exposure, the possible reason is that the concentration of secondary antibody is too high, or the concentration of primary antibody is too high, or the blocking solution is not suitable, change to other blocking solution. If the fluorescence is quenched quickly, the possible cause is that the fluorescence of the target band is too strong, resµLting in rapid consumption of ECL by HRP. If there is no luminescence signal, it may be that the target protein expression is very weak, which can prolong the tablet pressing time. 5. Wear a lab coat and disposable gloves during operation.

123.456,00 € 123456.0 EUR 123.456,00 € Hors taxes

123.456,00 € Hors taxes

Not Available For Sale

Cette combinaison n'existe pas.

This content will be shared across all product pages.


Hieff NGS

Conditions générales
Garantie satisfait ou remboursé de 30 jours
Expédition : 2-3 jours ouvrables


Référence interne: ECL02-01
URL de site web: /shop/ecl02-01-elisa-eclipicotm-ecl-chemiluminescence-29425

Our latest content

Check out what's new in our company !

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.